DTC Description
DTC DETECTION LOGIC
DTC No. | CONSULT screen terms (Trouble diagnosis content) | DTC detecting condition |
P0451 | EVAP SYS PRES SEN (Evaporative emission system pressure sensor/switch range/performance) | ECM detects a sloshing signal from the EVAP control system pressure sensor |
POSSIBLE CAUSE
FAIL-SAFE
Not applicable
DTC CONFIRMATION PROCEDURE
NOTE: Never remove fuel filler cap during DTC confirmation procedure.
1.PRECONDITIONING
If DTC Confirmation Procedure has been previously conducted, always perform the following procedure before conducting the next test.
With CONSULT>>GO TO 2.
Without CONSULT>>GO TO 5.
2.PERFORM DTC CONFIRMATION PROCEDURE-1
With CONSULT
NOTE: Do not depress accelerator pedal even slightly.
Is 1st trip DTC detected? YES >> Proceed to EC-328, "Diagnosis Procedure".
NO >> GO TO 3.
3.PERFORM DTC CONFIRMATION PROCEDURE-2
With CONSULT
NOTE: It will take at most 2 hours until “OFF” of “EVAP DIAG READY” changes to “ON”.
NOTE: Never turn ignition switch ON during 90 minutes.
Which is displayed on CONSULT? CMPLT>> GO TO 4.
YET >> 1. Perform DTC CONFIRMATION PROCEDURE again.
2. GO TO 1.
4.PERFORM DTC CONFIRMATION PROCEDURE-3
With CONSULT
Check 1st trip DTC.
Is 1st trip DTC detected? YES >> Proceed to EC-328, "Diagnosis Procedure".
NO >> INSPECTION END
5.PERFORM DTC CONFIRMATION PROCEDURE-4
With GST
NOTE: Do not depress accelerator pedal even slightly.
Is 1st trip DTC detected? YES >> Proceed to EC-328, "Diagnosis Procedure".
NO >> GO TO 6.
6.PERFORM DTC CONFIRMATION PROCEDURE-5
With GST
NOTE: Never turn ignition switch ON during 90 minutes.
Is 1st trip DTC detected? YES >> Proceed to EC-328, "Diagnosis Procedure".
NO >> INSPECTION END
Diagnosis Procedure
1.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR FOR WATER
Water should not exist.
Is the inspection result normal? YES >> GO TO 2.
NO >> Repair or replace harness connector.
2.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY
Is the inspection result normal? YES >> GO TO 4.
NO >> GO TO 3.
3.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR POWER SUPPLY CIRCUIT
Is the inspection result normal? YES >> Perform the trouble diagnosis for power supply circuit.
NO >> Repair or replace error-detected parts
4.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR GROUND CIRCUIT
Is the inspection result normal? YES >> GO TO 5.
NO >> Repair or replace error-detected parts.
5.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SIGNAL CIRCUIT
Is the inspection result normal? YES >> GO TO 6.
NO >> Repair or replace error-detected parts.
6.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Check the EVAP control system pressure sensor. Refer to EC-330, "Component Inspection".
Is the inspection result normal? YES >> GO TO 7.
NO >> Replace EVAP control system pressure sensor. Refer to FL-22, "Removal and Installation".
7.CHECK INTERMITTENT INCIDENT
Refer to GI-41, "Intermittent Incident".
>> INSPECTION END
Component Inspection
1.CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Always replace O-ring with a new one.
CAUTION:
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace EVAP control system pressure sensor. Refer to FL-22, "Removal and Installation".
Rear window wiper and washer switch
WARNINGIn freezing temperatures the washer solution
may freeze on the window and obscure
your vision. Warm the rear window
with the defroster before you wash the
rear window.
CAUTION
Do not operate the washer continuously
for more than 30 seconds ...
Back door finisher
Exploded View
Back door
Access cover
Back door finisher
Clip
Pawl
Metal clip
Removal and Installation
REMOVAL
Using a suitable tool (A) release upper LH most clip, then
release remaining clips by gently pulling down on back door finisher
(1).
: Clip
INSTA ...
DTC/circuit diagnosis
U1000 CAN COMM CIRCUIT
WITH INTELLIGENT KEY
WITH INTELLIGENT KEY : Description
Refer to LAN-8, "System Description".
WITH INTELLIGENT KEY : DTC Logic
DTC DETECTION LOGIC
NOTE:
U1000 can be set if a module harness was disconnected and reconnected, perhaps
during a repair. Confirm
...